3.8 Interruption of the flow meter

The flow meter is switched off by pressing the Start
key for about 5 seconds. The flow meter switches off
automatically being inactive for more than 90 seconds.

3.9 Maintenance

The flow meter housing and the connections must be
checked for damages and leaks regularly.
In case of a battery change, carefully open the flow meter
housing and remove the battery from bottom part of the
housing. Insert a new 3.6 V Lithium battery and lock
the housing.

3.9.1 Changing the batteries

The sum memory device and the calibration factor are
not cleared during battery change.
. Remove the 4 screws at the back-side of the flow
meter.
2. Carefully remove the display keyboard of the flow
meter with the display from the housing. Pay
attention to cable length!
3. Remove the 2 screws at the battery bracket.
4. Remove the battery from the bracket.
5. Insert the new battery, 3.6 V-Lithium-battery.
6. Screw on the battery bracket.
7. Carefully attach the display keyboard of the flow
meter with the display onto the housing. Make sure
that the cables cannot be pinched.
8. Screw on the 4 screws onto the back-side of the
flow meter.
Environment protection
Batteries and battery packs are containing dangerous
substances for the environment and the human health.
Do not dispose batteries and battery
packs into the domestic waste, into fire or
into water.
Batteries and battery packs must be
collected and recycled.
Within the EC countries you are legally
bound to return batteries and battery
packs after use to the sale shop or a
public collecting point. Taking back of bat-
teries and battery packs is free of charge.

3.9.2 Resetting the totals

. Remove the 4 screws at the back-side of the flow
meter.
2. Carefully remove the display keyboard of the flow
meter with the display from the housing. Pay
attention to cable length!
3. Remove the 2 screws at the battery bracket.
4. Remove the battery from the bracket.
5. Press the key „Reset" and at the same time re-
insert the battery into the bracket. The subtotals
 to 9 and the Total will be reset to 000000.
6. Screw on the battery bracket.
7. Carefully attach the display keyboard of the flow
meter with the display onto the housing. Make sure
that the cables cannot be pinched.
8. Screw on the 4 screws onto the back-side of the
flow meter.
C. Nozzle PP and automatic nozzle AdBlue
Caution!
Contaminated AdBlue may lead to disfunction of
the vehicle exhaust system.
Protect the outlet of the nozzle against
contamination.
Caution!
Overflowing liquid may reach the environment.
The lever of the nozzle PP " must not be
locked.
The nozzle PP " does not switch off
automatically!
D. Repairs
Repairs may only be carried out by the manufacturer or
authorized repair shops.
Before sending back the appliance, following must be
observed:
• The appliance must be completely emptied, rinsed and
cleaned.