General safety information

The operator must read the operating instructions
before starting the pump and follow these instruc-
tions during operation.
. The motor is not explosion proof.
The pump is not allowed to be operated in explosion
hazard areas.
. The motor must not be used to pump flammable
liquids.
3. The pump may only be operated in an upright posi-
tion.
4. The pump is a hand-held appliance and must not be
left unattended.
5. The pump must not be allowed to run dry. Switch off
immediately when the container is empty.
6. At low level of the container splash can occur at the
pump foot during operation. When pumping hazar-
dous liquids it is recommended to use containers
with cover.
7. The motor must not be immersed in the liquid being
pumped.
8. The pump operator must wear suitable protective
clothing, face mask or goggles, apron and gloves,
when pumping hazardous liquids.
9. Do not reach into the intake port of the pump.
0. Ensure that all connections and fittings are properly
tightened.
. Note the temperature limits.
. Ensure that the pump is resistant to the medium
being pumped.
3. Ensure that the motor is switched off before connec-
ting to the electricity supply.
The national accident prevention regulations must be
observed without fail.
8

1. General

1.1 Pump tube

The drum pump B is a sealless, vertical centrifugal
pump with axially acting rotor.
The pump is used to transfer pure, turbid, water-like,
aggressive and non aggressive liquids (see table 1 /
page 10).

1.2 Drive motor

The mains-powered motors have double insulation and
are splash proof (IP 4). All motors have interference
protection (see table 2 / page 10).

1.3 Scope of supply

Check that the consignment is complete (see Fig. 1).
The following is included in the scope of supply of the
pump with 3 m connecting cable and plug:
B2 pump
B2 pump set
 Hose connector
 Hose connector
for 3/4" hose
 Wing nut
 Wing nut
 Wall bracket
.5 m PVC hose
 Lutz nozzle, PP
 Hose clips 3/4"
 Curved spout
Item No.