A. Drum pump Lutz B2 AdBlue
General safety information
The operator must read the operating instructions
before starting the pump and follow these
instructions during operation.
. The pump is not explosion proof.
The pump is not allowed to be operated in explosion
hazard areas.
2. The motor must not be used to pump flammable
liquids (see Fig. 1).
3. The pump may only be operated in an upright
position.
4. The pump is a hand-held appliance and must not be
left unattended.
5. The pump must not be allowed to run dry. Switch
off immediately when the container is empty.
6. At low level of the container splash can occur at the
pump foot during operation. It is recommended to
use containers with a cover.
7. The motor must not be immersed in the liquid being
pumped (see Fig. 1).
8. Do not reach into the intake port of the pump.
9. Ensure that all connections and fittings are properly
tightened.
0. Note the temperature limits.
. Ensure that the pump is switched off before
connecting to the electricity supply.
When using a nozzle following must be additionally
observed:
2. Do not point the nozzle at persons.
3. The lever of the nozzle PP " must not be locked.
4. Protect the outlet of the nozzle against contamination.
The national accident prevention regulations must be
observed without fail.
4
1. Proper use
The drum pump Lutz B2 AdBlue is a sealless, vertical
centrifugal pump (see table 1, page 22).
The mains-powered motors have double insulation and
are splash proof (IP 24) (see table 2, page 22).
The pump Lutz B2 AdBlue is used for refueling of
AdBlue only. AdBlue is a non-toxic, clear, synthetically
manufactured solution and is used as reduction agent for
SCR-systems of diesel fuel driven vehicles.
Improper use or any changes can lead to serious risks.
The operator is responsible for any damages resulting
from improper use.
Caution!
Special risks for mankind and environment are
unknown when handling AdBlue.
The safety data sheet however must be
observed!
Caution!
AdBlue may create powdery residues. Thus it
may occur that seal- and coupling systems are
put out of operation.
Keep the containers closed and make sure that
connecting lines are sealed.
Caution!
AdBlue cannot be pumped at low temperatures.
The filling system may only be operated at
temperatures between -0°C and 30°C.
Caution!
When taking out AdBlue the container may
shrink due to a vacuum.
Use an appropriate ventilation system.
Caution!
Climatic influences and UV-rays may shorten life
of the refueling system.
Do not store the filling system outdoor over a
longer period.