3.7 Changing the unit of measurement between litres and US-gallons
(from serial no. 0213-00100 2000)
The unit of measurement can only be changed indirectly via the calibration factor.
Requirement: The partial quantity has been reset to 0.00.
Switching into calibration mode
Operation
At the same time press for approx. 5 seconds
Conversion
Multiply the indicated calibration factor with the conversion factor for the required unit of measurement:
Changing of:
Litres  US-gallons
US-gallons  Litres
e.g. 000 x 3,785 = 3785
Change calibration
or
Memorise volume detected
At the same time press for approx. 5 seconds
20
Conversion factor
3,785
0,264