23.5. Condensate drain

A wet floor resulting from overflow from the vessel poses a slip hazard.
Regularly empty the condensate collection tank.
Injury hazard.
Do not connect the condensate drain directly to a waste drain!
Passers-by may be injured.
Condensate is automatically drained into the condensate collection vessel.
Monitor the level in the vessel using the 1 l or 2 l markings
(depending on the volume of the vessel), and empty at least once a
day
Switch off the compressor every time before emptying the tank!
Before the following checks it is required:
Compressor with cabinet – release the door lock and open the cabinet door.
23.6. Check of safety valve
 Turn the screw (2) on the safety valve (1) several
times to the left until the safety valve releases the
air.
 Let the safety valve vent for a few seconds.
 Turn the screw (2) fully to the right, the valve must
be closed now.
Risk of pressure increase when safety valve is damaged.
Safety valve must not be used to depressurize the air tank. It could damage the
safety valve function. The valve is set to the maximum allowed pressure, it is tested
and marked.
Safety valve setting must not be adjusted.
NP-DK50 2V-3_10-2022-AD
Fig. 18: Check of condensate collection vessel
Fig. 19: Check of safety valve