Setup menu: level 1

General

The digital power sources come with a wealth of expert knowledge already built
in. You can retrieve and use any of the optimised parameters stored in the machi-
ne whenever you wish.
The Setup menu provides simple access to this expert knowledge plus some ad-
ditional functions. It enables the parameters to be easily adapted to the various
tasks.
Accessing the
The mode of operation is explained here with reference to the "MMA welding"
Setup menu for
process. The procedure for changing other Process parameters is identical.
Process parame-
ters
The available parameters can be set separately for all welding processes that can
be selected using the Process button (3). The parameter settings are stored until
the respective set value is changed.
1
2
3
4
5
6
The power source is now in the Setup menu for the "MMA welding" process - the
first HCU (HotStart current) parameter is displayed.
Changing wel-
1
ding parameters
2
Exiting the Set-
up menu
Example for the "MMA welding" process
96
Plug in the mains plug
Set the mains switch (8) to the "I" position
Press the Process button (3) to select the "MMA welding" process
Press and hold the Setup / Store (7) button
Press the Process button (3)
Release the Setup / Store (7) button
Use the Process button (3) to select the desired parameter
Use the adjusting dial (1) to alter the value of this parameter
Press the Setup / Store button (7)
1
IMPORTANT! Any alterations are
saved by exiting the Setup menu.
The Setup menu for the processes
"MMA welding with Cel electrode" and
"Special processes" is the same as the
"MMA welding" process menu.
A complete list of parameters for the
"MMA welding" process can be found
in the "Process parameters" section.