Herunterladen Inhalt Inhalt Diese Seite drucken

Parameters; Mma Welding; Tig Welding - Fronius TransPocket 4000 CEL Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TransPocket 4000 CEL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameters

MMA welding

The HCU (HotStart current) function and available setting range are described in
the section headed "MMA welding".
HCU
HotStart current
Unit
Setting range
Factory setting
Hti
Hot-current time
Unit
Setting range
Factory setting
FAC
Factory - reset power source
Press and hold the Setup / Store button (7) for 2 s to reset the device to its
original (i.e. factory) settings. If the display reads "PrG", then the power source
has been reset
IMPORTANT! When the power source is reset, all personal settings in the Le-
vel 1 Setup menu are lost.
The functions in the second level of the Setup menu (2nd) are also deleted.
2nd
Second level of the Setup menu (see section "Setup menu: level 2")

TIG welding

2nd
Second level of the Setup menu (see section "Setup menu: level 2")
m/min
0 - 100%
50%
s
0 - 2.0 s
0.5 s
97

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Transpocket 5000 celTp 4000 celTp 4000 cel mvTp 5000 celTp 5000 cel mv

Inhaltsverzeichnis