Herunterladen Inhalt Inhalt Diese Seite drucken

Danger From Shielding Gas Cylinders; Safety Measures At The Installation Location And During Transport - Fronius TransPocket 4000 CEL Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TransPocket 4000 CEL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Use filters if necessary.
Danger from
Shielding gas cylinders contain gas under pressure and can explode if damaged.
shielding gas cy-
As the shielding gas cylinders are part of the welding equipment, they must be
linders
handled with the greatest of care.
Protect shielding gas cylinders containing compressed gas from excessive heat,
mechanical impact, slag, naked flames, sparks and arcs.
Mount the shielding gas cylinders vertically and secure according to instructions
to prevent them falling over.
Keep the shielding gas cylinders well away from any welding or other electrical
circuits.
Never hang a welding torch on a shielding gas cylinder.
Never touch a shielding gas cylinder with an electrode.
Risk of explosion - never attempt to weld a pressurised shielding gas cylinder.
Only use shielding gas cylinders suitable for the application in hand, along with
the correct and appropriate accessories (regulator, hoses and fittings). Only use
shielding gas cylinders and accessories that are in good condition.
Turn your face to one side when opening the valve of a shielding gas cylinder.
Close the shielding gas cylinder valve if no welding is taking place.
If the shielding gas cylinder is not connected, leave the valve cap in place on the
cylinder.
The manufacturer's instructions must be observed as well as applicable national
and international regulations for shielding gas cylinders and accessories.
Safety measures
A device toppling over could easily kill someone. Place the device on a solid, level
at the installati-
surface such that it remains stable
on location and
-
during transport
Special regulations apply in rooms at risk of fire or explosion
-
Use internal directives and checks to ensure that the workplace environment is
always clean and clearly laid out.
Only set up and operate the device in accordance with the degree of protection
shown on the rating plate.
When setting up the device, ensure there is an all-round clearance of 0.5 m (1 ft.
7.69 in.) to ensure that cooling air can flow in and out freely.
When transporting the device, observe the relevant national and local guidelines
and accident prevention regulations. This applies especially to guidelines regar-
ding the risks arising during transport.
Do not lift or transport operational devices. Switch off devices before transport
or lifting.
The maximum permissible tilt angle is 10°.
Observe relevant national and international regulations.