  • DEUTSCH, seite 15
3.3.4

Overview of the terminal assignment

This overview indicates which system parts can be connected for all
terminals in the module. Depending on the system, one of the
components can be connected to the terminal (e.g. "VR2" or "PR2" to the
terminal "VR2"). Depending on what the module is used for,
simultaneous connection of a number of components may be required,
or may need to be excluded.
120/230VAC 120/230VAC
4
43 44
N
N
N L
N L
M
M
M
M
VR1
VR2*
PR1
230 V AC
PR2*
Legend for the Fig. above and Fig. 20 to 28at the end of the document:
grau
Components with a grey background can be connected as an
option
*
Components of the system are possible alternatives
230 V AC Mains voltage connection
AHS/AWE Alternative heat source with signal input; extra-low voltage or
mains voltage side (Alternative Heat Source)
AHSP
Alternative heat source without signal input
(Alternative Heat Source Passive)
B
Buffer cylinder (Buffer)
BC
Basic Controller
CC
Combi Cylinder
CHC
Conventional heat source: Combi Heating Centre
CON
Control unit with BUS system EMS 2, e.g. operated in an
integrated system of conventional and alternative heat
source and code switch setting 1, e.g. C 400/C 800, UI 800
(Controller)
ME 200 – 6721841615 (2021/11)
120/230 V AC
VR2
VR1
PR1
N 14
N
43 44
N 14
120/230 V AC
VB1
OA3
N L
N
L
N 43
44 15
16
4
43 44
N
M
VB1
230 V AC
AHS/
AWE
ME 200
4 5 6
3
7
2
8
1
9
10
10
0
≤ 24V
TR1 TB1
TB2 TB3
TB4 TA1
1 2 1 2
1 2 1
2 1
≤ 24V
OA1
OA2
T1
TR2
OEV
on/off
0-10V
1 2 1 2
1 2 1
2 3
N
T1
TR2
HS
AHS/
AWE
CONM
Control unit with BUS system EMS 2, e.g. signal input/output
for systems with stand-alone alternative heat sources and
coding switch setting 9 or 10, e.g. C 400/C 800
(Controller Master)
DHWC
DHW cylinder (Domestic Hot Water Cylinder)
HN
District heating system (Heating Network)
HS
Conventional Heat Source
Connection HS to OEV only with control units with EMS; for
control unit series MX 25 from V1.44, this connection is not
required
FS
Freshwater Station
MC
Master Controller
Rel
Relay
SLP
Primary store system
SM/MS
Solar Module
OR1
TF1
TF1
2
1 2
3
4
1
2 3
BUS
BUS
BUS
Adr.9-10
4
1 2
1
2
1 2
CONM
CON
CON
TR1
TB1
BC/MC
BC/MC
(autark)
Installation
1 2 3
PWM
0-10V
PR1
TB2
TB3
TB4
TA1
0010016173-004
35