Symbols and Definitions

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in moderate or minor injury.
Indicates information considered important but not directly hazard related.

Safety Information

To ensure a safe installation and proper equipment operation, please read, understand, and adhere to all DANGER/WARNING/CAUTION and other NOTICES.
Electrical wiring should be performed with extreme caution and in compliance with local, state, and national electrical
code NEC/ANSI/NFPA 70, NFPA 30, and NFPA 30A, as appropriate for the intended use of the pump. Threaded rigid
conduit, sealed fittings, and conductor seal should be used where applicable. The pump must be properly grounded. If
installing in deviation of this manual, a licensed electrician must perform the installation. Improper installation or use
of this product will result in serious bodily injury, or death!
To ensure safe and proper operation of your equipment, it is critical to read and adhere to all of the following safety
warnings and precautions. Failure to follow instructions below, improper installation, or use of this product, will cause
serious bodily injury or death!
To minimize static electricity build up and possible explosion, use only static wire conductive hose when pumping
flammable fluids, and keep the fill nozzle in contact with the container being filled during the filling process. Spark/
static discharge will cause explosions.
Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the
possibility of leaks. Leaking fuel may cause the potential for fire and explosion.
The pump motor is equipped with thermal overload protection; if overheated, the motor will shut off to prevent damage
to the windings. If this happens, you must turn off the pump power to reset this safety feature, and turn the pump back
on when it has cooled to continue use. The pump will not restart until properly cooled.
This product is not suited for use with fluids intended for human consumption or fluids containing water. Materials of
construction are not food grade. The pump is water tolerant, however, extended use with water will shorten the life of
the vanes, and can cause swelling of the rotor. Flush / drain the pump after pumping water to be certain water does not
stand in the pump body to prevent premature wear. Flush with a petroleum product (gasoline, diesel, light oil, etc) to
eradicate residual water.
A Fill-Rite Filter should be used on the pump outlet to ensure no foreign material is transferred to the fuel tank. Foreign
material can damage the equipment being fueled.
fillrite.com
RD SERIES FUEL TRANSFER PUMPS
NEVER smoke near the pump, or use the pump near open flames when pumping a flammable liquid! Fire can result!
This product shall not be used to transfer fluids into any type of aircraft due to spark / static discharge possibility.
Spark/static discharge will cause explosions.