Menu item
Description
[EN]
[DE]
Empty pipe
The solenoid valve is opened
23
so that the pipe can be
[EmptyPipe]
drained. The red LED flashes
[RohrLeer]
twice every 6 s. The function
switches off automatically after
30 minutes.
Factory setting
All functions are reset to
24
factory settings. The red LED
[FactrySet]
flashes three times and a flush
[Werkseinst]
is actuated. The urinal flush
control is restarted.
Activate cleaning mode
The red LED flashes twice
25
every 3 s. The flush actuation
[CleanMode]
is suppressed for the [cleaning
[Reinigung]
time] (menu item 55). The
urinal flushes at the end of this
duration.
Programmes
Activate covered urinal
operation
In the case of urinals with lids,
30
the open urinal lid can cover
[CoverOps]
the IR sensor. In covered
[Deckel-UR]
urinal operation, a flush is
actuated as soon as the urinal
lid is closed.
Enable manual flush
31
An early manual flush can be
[ManFlshEn]
actuated by the user placing
[FreiManSp]
their hand near the IR sensor.
18014405597129227 © 05-2022
971.384.00.0(00)
Application
• To carry out
maintenance work
• To carry out winter
emptying
• To remedy
malfunctions
• To clean the cover
plate and urinal
ceramic without the
water running
• For urinals with lid
• To actuate a manual
flush during use
Area
Factory setting
On = <OK>
–
Off = <OK>
Start = <OK>
–
Start = <OK>
–
On = [ON]
Off
Off = [OFF]
On = [ON]
Off
Off = [OFF]
EN
2 / 4
31