38
Error code
Description
50xx
Load cell with address xx not supplying
measured value
51xx
Load cell with address xx has incorrect F
number
52xx
Load cell with address xx has incorrect TRC
status
5701
Vehicle empty weight > Weighing2 result
5702
Weighing result < minimum vehicle weight
5703
Weighing result > maximum vehicle weight
5801
Measurement invalid
5802
No standstill
Error code
Description
6001
Measured value differences in corners too
large
6002
Zero point outside off-center load range cannot
be compensated
6003
Nominal value outside off-center load range
cannot be compensated
Error code
Description
7001
Yard list full (50 entries)
7002
Database error
Error code
Description
8x01
Input buffer overflow
8x02
Overrun
Possible causes:
Incorrect baud rate, parity settings
8x03
Parity error
Possible causes:
Incorrect baud rate, parity settings
8x04
Framing error
Possible causes:
Incorrect baud rate, parity settings
8x05
Framing error
Possible causes:
Incorrect baud rate, parity settings
x represents the interface e.g. 8101 error at COM1, 8201 error at COM2, etc.
HBM
Measurement
Off-center load compensation
Database
COM1−4 interfaces
Remedy
Carry out busscan or test load cell (Test
menu), emergency operation possible if
only one load cell fails per segment
Reload load cell with parameters (Menu
Adjust/Repair) or replace load cell
Reload load cell with parameters (Menu
Adjust/Repair) or replace load cell
Check vehicle data
Repeat measurement if necessary
Adjust minimum vehicle weight
Vehicle loaded
Adjust maximum vehicle weight
Vehicle overloaded
Printout measured value at 0
Printout 2x same measured value
Standstill conditions not applicable
during measured value printout
Remedy
Check scale construction
Remedy
Repair database (Menu FACTORY
SETTINGS−DATABASE)
Remedy
Carry out a BUSSCAN
Carry out a BUSSCAN
DIS2116
A2540-1.1 en/de