Herunterladen Inhalt Inhalt Diese Seite drucken

HBM DIS2116 Kurzanleitung Seite 34

Waagenelektronik
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

34
Center of gravity display for a scale consisting of 1 segment and 4 load cells.
The individual load cells are displayed with their addresses; in this example
segment 1 with the addresses 11 .... 14. The determined center of gravity is
marked by an "X. "Error" is displayed if the scale platform is lifted.
No center of gravity is determined with a load of < 1 d, the message "No load"
is displayed.
NOTE
To ensure that the center of gravity determination works correctly, the load cell
addresses must be assigned clockwise during scale configuration as shown in
the center of gravity determination example above. If the scale consists of se-
veral segments, the load cell arrangement must be implemented the same
way in each segment.
ADR 11
ADR 12
Segment 1
ADR 14
ADR 13
Fig.: Address assignment for 3 segments
ADR 11
ADR 14
Fig.: Center of gravity determination with 3 segments as a compound scale
Only the outer 4 load cells are shown in the center of gravity window.
HBM
ADR 21
ADR 22
Segment 2
ADR 24
ADR 23
X
ADR 31
ADR 32
Segment 3
ADR 34
ADR 33
ADR 32
ADR 33
DIS2116