2.3.4 Electrical Connection

The storage heater appliance is connected to a load current (OFF-PEAK tariff) and control cables
for the room thermostat and for the charge control (A1/Z1; A2/Z2). The cables A1/Z1 and A2/Z2
are at line-voltage 230V~ and may thus be run together with a L/N/PE cable for the room
thermostat. The heater is suitable for direct connection without a spur, or with a wall socket.
According to regulations every branch circuit must be individually protected, for instance by
circuit breakers for all phases. These circuit breakers must have contact openings of at least
3 mm.
Each heater must be connected to a separate current carrying cable from the electrical
junction box. Running the load current cable from heater to heater is not allowed.
Since the technical connection conditions stipulated by the power supply companies permit a
1-phase connection of up to 2 kW only, the appliance must always be connected to 3 phases.
When connecting to a charge control with a so-called "single-wire control", bridge the
terminals "A2/Z2" and "N".
Make sure the earth wire is correctly and firmly attached.

2.3.5 Cable Feed

Fig. 9
For the Fitter