For the Fitter
Pull the connection cords of the heating
elements completely through the openings
prepared and bow the connection cords at the
coloured bushes carefully (Fig. 6).
Caution: Do not push the connection cords
Fit the upper insulation mats tightly onto the
cover bricks (Fig. 7).
Caution: Do not mix up upper insulation

2.3.2 Element Ratings

You can choose from 3 different power ratings.
Connect the heating elements on to the terminal strip X2 depending on the power rating chosen
according to the circuit diagram (page 28). The terminal strip is on the left hand side of the heater
on the inside panel.
Cover up the non-applicable power ratings on the heater rating label (bottom right of heater) with
the label provided (in the bag with the wall-fixing screw) – see example of rating label on page 29.
For this, remove the protective paper from the adhesive side of the label. Position the adhesive side
on the power rating to be covered by means of the frame-outline printed on the rating label. Press
the covering label firmly and then remove the carrier foil. Proceed in the same way for the second
rating to be covered.
Tip: It is easier to cover the rating if the edges of the label are cut off beforehand.
Put a cross against the chosen rating in the circuit diagrams, both in the Instruction Leaflet, and in
the right hand inside panel.
Connect the heating elements to the charge control according to circuit diagram (page 28).
Be careful that the capillary tubes do not touch live parts.
The heater is then re-assembled as described in Part 1-7 on page 24, but in reverse order.

2.3.3 Disassembly of Fan Drawer

For disassembly of drawer (e.g. for maintenance
works) unscrew the air-outlet grille, release the
inner screws (D) on the right and left side, turn
them off about 15 mm and press them back.
Remove right side panel.
Pull out the fan connection cable and the drawer.
When reassembling the drawer pull back the
connection cable into the lateral control panel
room and tighten the two screws (D) firmly.
See that the drawer does not surpass the bottom
plate of the heater at the front.
Refasten (finger-tight) right side panel and air
outlet grill.
26
backwards to the interior.
during installation!
Inner upper
insulation
15x242x455
Fig. 7 Upper insulation
D
Fig. 8 Disassembly of fan drawer
Outer upper
insulation
10x270x505