Disassembly and cleaning

Disassembly and cleaning
For complete cleaning and replacement of components, the progressive cavity pump must
be disassembled. Disassembly is almost identical for both the motor flange version and the
gearbox version. Disassembly for cleaning is described below based on the motor flange ver-
sion. Each disassembly step must be followed by cleaning the disassembled component.
The progressive cavity pump must be cleaned after each use.
NOTICE
During disassembly and assembly, the progressive cavity pump should be fixed with a vice with
suitable half shells.

10.1 Safety

DANGER
Explosion and fire hazard
Risk of death from explosions and fires when working in potentially explosive
atmospheres.
 Do not carry out disassembly in potentially explosive atmospheres.
 Read chapter 2.4 Working in potentially explosive atmospheres.
DANGER
Vapours hazardous to health
Depending on the pumped medium, there is a risk of death due to hazardous gases.
 Use respiratory protection.
 Use eye protection.
WARNING
Hot surfaces
Depending on the pumped medium, there is a risk of burns on hot surfaces of the
progressive cavity pump and peripherals.
 Use heat-resistant hand protection.
Operating instructions VISCOPOWER