Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Originalanhang
Original attachment
Annexe originale
All manuals and user guides at all-guides.com
Anhang Ex-Schutz-Informationen Fass- und Behälterpumpen
Explosionsschutz
Fass- und
Containerpumpen
Seite 3 – 8
Ex-Protection
drum and
container pumps
Page 9 - 14
Protection
antidéflagrante
pompes vide-fûts
Page 15 – 20
1 / 24

Werbung

loading

Inhaltszusammenfassung für FLUX FP 424 Ex S Serie

  • Seite 1 All manuals and user guides at all-guides.com Originalanhang Original attachment Annexe originale Explosionsschutz Fass- und Containerpumpen Seite 3 – 8 Ex-Protection drum and container pumps Page 9 - 14 Protection antidéflagrante pompes vide-fûts Page 15 – 20 Anhang Ex-Schutz-Informationen Fass- und Behälterpumpen 1 / 24...
  • Seite 2 All manuals and user guides at all-guides.com Achtung Lesen Sie die allgemeine Betriebsanleitung für Fass- und Containerpum- pen und die mitgelieferten produktspezifischen Anhänge, bevor Sie die Pumpe in Betrieb nehmen! Lesen Sie vor dem Fördern brennbarer Flüssigkeiten bzw. bei Verwendung des Motors oder der Pumpe im explosionsgefährdeten Bereich unbedingt den Anhang „Explosionsschutz Fass- und Containerpumpen“.
  • Seite 3 All manuals and user guides at all-guides.com Sicherheit Bestimmungsgemäße Verwendung Die Fasspumpen dienen dem schnellen und sicheren Entleeren oder Umfüllen von Fässern, Containern und Behältern. In explosionsgefährdeter Umgebung kommen Pumpen und Motoren zum Einsatz, die nach der gültigen Explosionsschutzrichtlinie geprüft und zugelassen sind. Sicherheitshinweise Alle Sicherheitshinweise müssen beachtet und befolgt werden.
  • Seite 4 All manuals and user guides at all-guides.com  Beim Einsatz der Pumpen und Motoren im explosionsgefährde- ten Bereich dürfen keine Motoradapter verwendet werden.  Der Motor darf erst eingeschaltet werden, wenn die Pumpe in der Flüssigkeit steht.  Kein Trockenlauf. ...
  • Seite 5 Gerätebeschreibung Abb. 1: Aufbau der Pumpe (mit Komponenten) Ex-geschützt Position Bezeichnung Ex-geschützter Antriebsmotor in verschiedenen Ausführungen Fasspumpe (Pumpenrohrsatz) in verschiedenen Ausführungen und Werkstoffen (siehe Kapitel 6, Seite 8) FLUX-Clip Fußsieb Fassverschraubung FES Emissions-Schutzventil mit Gewindering Schlauchleitung in verschiedenen Ausführungen Schlauchfassung Zapfpistole in verschiedenen Ausführungen und Werkstoffen...
  • Seite 6 All manuals and user guides at all-guides.com Inbetriebnahme im explosionsgefährdeten Bereich Achtung!  EG-Baumusterprüfbescheinigung bzw. Konformitätsbescheini- gung beachten.  Die Pumpentypen F ... dürfen im explosionsgefährdeten Bereich nicht ortsfest eingesetzt werden und müssen ständig überwacht werden.  Die Pumpentypen FP … Ex S dürfen im explosionsgefährdeten Bereich ortsfest eingesetzt werden, müssen aber trotzdem stän- dig überwacht werden.
  • Seite 7 All manuals and user guides at all-guides.com Herstellung eines Potentialausgleichs Werden die Motoren zusammen mit der Pumpe betrieben, ist ein umfassender und eindeutiger Potentialausgleich unerlässlich (Erdung, Abb. 2). Alle Geräte / Komponen- ten vor der Verwendung im explosionsgefährdeten Bereich in das Potentialausgleichs- system einbinden.
  • Seite 8 All manuals and user guides at all-guides.com Maßnahmen nach Benutzung Reinigung der Pumpe Achtung!  Die Pumpe und das Netzanschlusskabel nur außerhalb des explosionsgefährdeten Bereiches reinigen. > Die Pumpe mit einem geeigneten Reinigungsmittel durchspülen. > Pumpe nur bis zum Auslaufstutzen in das Reinigungsmittel tauchen. >...
  • Seite 9 All manuals and user guides at all-guides.com Safety Intended Use The drum pumps are used for quick and save liquid transfer or emptying of tanks, barrels and containers. In an environment subject to explosion hazard, pumps and motors are used which have been checked and approved according to the valid Explosion Protection Directive.
  • Seite 10 All manuals and user guides at all-guides.com  Do not use a motor adapter when pump and motor are used in hazardous areas.  Only switch on the motor when the pump is in the liquid.  No dry running. ...
  • Seite 11 Position Designation Ex-proof drive motor in various designs Drum pump (pump tube set) in various designs and materials (see chapter 6, page 14) FLUX-Clip Suction strainer Compression gland Fume gland type FES Flexible hose in various designs Swaged hose fitting...
  • Seite 12 All manuals and user guides at all-guides.com Transport Information on transport in an ex-protected area: > Prevent electrostatic charge build-up during transport. > Observe internal operating instructions. Commissioning in explosive environments Attention!  Observe the EC type examination certificate and the certificate of conformity, respectively.
  • Seite 13 All manuals and user guides at all-guides.com Equipotential bonding If the motors are operated together with the pump, comprehensive, clear equipotential bonding is essential (earthing, Fig. 2). All devices / components have to be integrated into the equipotential bonding system prior to use in hazardous areas. Ω...
  • Seite 14 All manuals and user guides at all-guides.com Measures after use Cleaning pump Attention!  Only clean the pump and the power lead outside the hazardous area. > Rinse the pump with an appropriate detergent. > The pump should only be immersed into the detergent up to the outlet connection. >...
  • Seite 15 All manuals and user guides at all-guides.com Sécurité Utilisation conforme Les pompes vide-fûts servent à transvaser ou à vider, rapidement et en toute sécurité, des fûts ou d’autres contenants. En zone à risque d’explosion, n’utilisez que des pompes et des moteurs conçus et certifiés selon la directive relative à...
  • Seite 16 All manuals and user guides at all-guides.com  Lors de l'utilisation de la pompe et du moteur en zone explosible, aucun adaptateur de moteur ne doit être utilisé.  Mettre d'abord le moteur en marche avant de plonger la pompe dans le produit.
  • Seite 17 Position Désignation Moteur ADF en diverses exécutions Pompe vide-fûts (tube plongeur) de différents modèles et en différents matériaux (voir chapitre 6, page 20) FLUX-Clip Crépine inférieure Dispositif de vissage sur bonde de fût Dispositif anti-émanations type FES Tuyau flexible Raccord à douille Pistolet de remplissage de différents modèles et en...
  • Seite 18 All manuals and user guides at all-guides.com Transport Consignes de transport dans la zone antidéflagrante : > Eviter un chargement électrostatique lors du transport. > Respecter la réglementation en vigueur sur le site d’exploitation. Mise en service dans une atmosphère explosible Avis ! ...
  • Seite 19 All manuals and user guides at all-guides.com Etablissement d'une liaison équipotentielle Si les moteurs sont utilisés avec la pompe, leur raccordement équipotentiel est indispensable ( mise à la terre, fig. 2 ). Tous les appareils / composants doivent être intégrés dans le système d’équipotentialité avant d'être utilisés dans des zones à risque d’explosion.
  • Seite 20 All manuals and user guides at all-guides.com Mesures à prendre après l'utilisation Nettoyage de la pompe Attention !  Ne nettoyer la pompe et le câble d'alimentation qu'en dehors des zones à risque d’explosion. > Rincer la pompe à l'aide d'un détergent adéquat. >...
  • Seite 21 All manuals and user guides at all-guides.com 21 / 24...
  • Seite 22 All manuals and user guides at all-guides.com 22 / 24...
  • Seite 23 All manuals and user guides at all-guides.com 23 / 24...
  • Seite 24 All manuals and user guides at all-guides.com...