 Make sure that electrical connections are not damaged.
 PTFE stators and the rotors are Ex-marked on the front. Only these may be used as
spare parts.
 If the Ex symbol is no longer recognisable, the respective parts must be replaced.

11.2 Maintenance schedule

Component
O-rings
O-rings
Mechanical seal
Mechanical seal
Mechanical seal
Progressive cavity pump
Sliding surfaces of the mechanical seal
Fitting of the mechanical seal on the
shaft
Coupling
Progressive cavity pump
Hose clamps and hose fittings
Gearbox
Motor flange
122
Maintenance and servicing
Maintenance activity
Regular visual inspection for wear
Replace when worn
Regular visual inspection for wear
Replace when worn
Clean after each use
Visual inspection for leakage
Lubricate after cleaning, before commissioning and after
prolonged standing time (recommended grease: Klüber-
synth UH1 14-151)
Lubricate after cleaning, before commissioning and after
prolonged standing time (recommended grease: Klüber-
synth UH1 14-151)
Regular visual inspections for wear
Clean after each use
Regularly check for secure fitting
Regularly check for ease of movement and absence of
clearance and replace if necessary
Check bearings and freewheel regularly for ease of
movement and absence of clearance and replace if
necessary
Operating instructions VISCOPOWER