Operation
automatically, after a certain time of inactivity. It can be set in SETTINGS MENU.
Status display: Key lock key active, door open
If you press on any other key, Key lock key will blink fast, 2 times. Press on any other key is ignored.
Exeption: In case that any of the alarms is triggered, short press on alarm key
alarm.
Key lock mode deactivation:
with a 3 seconds press on Key lock key

Alarms

Please refer also to chapter "Tips & Tricks" to learn more about possible reasons for each particular
alarm.
Temperature alarm
Temperature alarm sounds when the temperature in the appliance is out of range, for 3 hours
constantly. This means 3°C above or 3°C below the setpoint temperature.
The alarm key
INFORMATION!
Every time the appliance is switched on again, it takes a while until the correct temperature is
reached. For this reason, the alarm is disabled for the first 6 hours after the appliance is switched
on to prevent the unnecessary activation of the alarm. Each time the door is closed, temperature
alarm is blocked for 3 hours.
If the difference between old setpoint and new setpoint is:
less than 5°C, it has no influence on temperature alarm,
between 5 and 10°C, temperature alarm is blocked for 24h,
higher than 10°C, temperature alarm is blocked for 80h.
Stopping the alarm:
Short press on alarm key will stop the alarm from sounding, alarm key is not illuminated anymore.
Setpoint temperature continues to blink while the temperature is still out of range. If the temperature
is within range and temperature alarm is active, it will be canceled automatically.
28
and setpoint temperature
.
are blinking.
will cancel the