Installation and connection
12
Place the appliance at least 50 mm away
from an electric or gas stove, and at least
300 mm away from a heat source (e.g. a
radiator or a heater). If such clearance is
not possible, then install an insulation
panel.
Do not expose the appliance to direct
sunlight.
We recommend free-standing installation
of the appliance. When necessary, it can
also be placed adjacent to cabinetry, if
adequate ventilation and cooling of the
installation location (e.g. air-conditioning)
are provided. In such a case, the
appliance power consumption is likely to
increase.
There has to be a clearance of at least 50
mm between the appliance and any
cabinet above it.
To allow for adequate ventilation and
cooling of the appliance, there has to be
sufficient clearence behind the appliance
and on both sides as well (at least 50 mm).
Please, also observe the clearance
required to fully open the door in order to
allow pulling out the drawers and shelves
(see installation diagram).
In cases of installation where there is less
than 50 mm of space around the cabinet,
a recess must be made at the ventilation
grilles on both sides of the appliance
(ventilation grilles must not be blocked)
which must be able to supply or exhaust
air on each side through an opening of at
2
least 200 cm
.
Furthermore, the 50 mm distance from the
rear wall must always be maintained and
must be connected to an opening above
or behind the cabinet.