Herunterladen Inhalt Inhalt Diese Seite drucken

Care And Maintenance - Kärcher NT 30/1 Tact Te H Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für NT 30/1 Tact Te H:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6. Set the minimum volume flow on the turn switch for
suction hose cross section. The scale shows the
suction hose suction hose cross section.
Note
The different suction hose cross sections are necessary
in order to adapt to the different connection cross sec-
tions of the processing machines.
Note
For operation as a dust removal device for mobile oper-
ation (processing machine plugged into the vacuum
cleaner) the integrated monitoring system must be ad-
justed to suit the connected processing machine (dust
generator). This means that the user must be warned
when the flow rate drops below the minimum value 20
m/s needed for correct vacuuming.
Note
Information on the minimum flow rate depending on the
vacuum can be found on the type plate.
Automatic filter dedusting
The device is equipped with a special filter dedusting
function, which is particularly effective against fine dust.
The flat fold filter is automatically cleaned every 7.5/15/
60 seconds (depending on use) using an airflow (puls-
ing sound).
1. Set the turn switch to program 2 (TACT AUTO).
2. Power dedusting (for particularly severe contamina-
tion of the flat fold filter): Set the turn switch to pro-
gram 2, seal the suction pipe or bender with your
hand and wait for the automatic filter cleaning to fin-
ish (lasts 15 seconds).
Illustration P
Switching off the device
1. Switch off the device at the turn switch.
2. Pull out the mains plug.
Each time after use
1. Empty the container.
2. Vacuum off the inside and outside of the device and
clean with a moist cloth.
Folding the push handle in/out
NT 50/1 only:
1. Release the push handle lock and adjust the push
handle.
Storing the device
1. Store the suction hose and mains cable as shown in
the illustration.
Illustration Q
2. Store the device in a dry room and secure it against
unauthorised use.
Transport
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transporta-
tion.
When transporting the device, ensure that it is securely
fastened.
The following measures must be taken for the dust-free
transport of the device:
1. Place the suction hose with accessories in the trans-
port bag supplied. Close the transport bag. Order
number for transport bag: 6.277-454.0
2. Close the suction connection, see wet vacuum
cleaning.
18
3. Remove the suction hose with floor nozzle from the
support. Carry the device by the carrying handle and
the suction pipe, not by the push handle.
4. When transporting the device in vehicles, secure it
to prevent it from slipping or overturning in accord-
ance with the respective valid guidelines.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
The device may only be operated indoors.

Care and maintenance

DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Dust extraction machines are safety devices for the pre-
vention or elimination of hazards according to the Ger-
man DGUV regulation 1 (German accident prevention
regulation, principles of prevention).
Note
Industrial vacuums/dust removal devices must be ser-
viced as required, but at least once a year, repaired if
necessary and checked by an expert (qualified in ac-
cordance with TRGS 519 No. 5.3, Paragraph 2). The
test result must be presented on request.
ATTENTION
Care agents containing silicone
These can attach plastic components.
Do not use care agents containing silicone for cleaning.
● You can perform basic maintenance and care work
yourself.
● Clean the surface of the device and the interior of
the container regularly with a moist cloth.
Replacing the flat fold filter
DANGER
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Accumulated dust must be transported in dust-proof
containers. Do not transfer the contents. Waste that
contains asbestos must be disposed of in accordance
with the instructions and rules for waste disposal. The
dust bag may only be disposed of by qualified staff.
WARNING
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not use the main filter element after removing it from
the device.
Permanently installed filters may only be replaced by an
expert in a suitable area (i.e. decontamination stations).
Order number for flat fold filter: 6.907-671.0 or 6.904-
242.0 (material marking B)
1. Turn both fastening pins of the filter cover counter-
clockwise with a screwdriver. Fastening pins are
pushed out.
Illustration R
2. Open the filter cover.
3. Remove the filter frame.
Illustration S
4. Remove the flat fold filter.
English
Storage

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nt 40/1 tact te hNt 50/1 tact te h

Inhaltsverzeichnis