Verfügbare Sprachen

INSTALLATION AND CIRCUIT - Electricity
OPTIONS
A
Bilge fan
Radio
Depth sounder
GPS
Searchlight
Alarm system
Refrigerator
VHF
Σ
WARNING
You may connect the options directly to the positive and negative console bus bars (within the
max. power limits), using an approved fuse-holder.
Some manufacturers will indicate the amperage rather than the absorbed
power. For direct current (the case here), simply multiply by 12 to obtain
NOTE:
the power and divide the power by 12 to obtain the device's current
consumption.
WIRING
1
Choose a free fuse location.
Connect the power supply of your accessory to the terminal corresponding to this slot
using a 6mm female tab type terminal lug.
If you have to add cable for the connection, use cable with a cross-section of at least
1.5mm² complying with "navy" type recommendations (UL1426 or SAE J378 or SAE J1127
or SAE J1128 or in general meeting ABYC and/or EC recommendations).
Connect the earth cable of your accessory to the ground terminal strip using a Ø5 "ring
terminal" (same remark as previously for the cable),
Insert an ATO type fuse with a max current of 15A and greater than the load current of
your device.
an
d
180W max.
You must make sure that the total power of the accessories in
column A you add is 180W (15A) or less AND that the max
power of an accessory in column B is 60W (5A) or less.
The sections of the cables in the wiring harness were calculated
using these values; if this rule is not adhered to, electrical
malfunctions and short-circuits may result.