FUNCTION SELECTION AND SETTING
Items
Optional Function
FE
Not prepared
FF
Not prepared
H1
Not prepared
H2
Indication of hot start
H3
Not prepared
H4
Not prepared
J1
Temperature indication (*8)
J2
Not prepared
J3
Run indicator color
J4
Not prepared
J5
Not prepared
J6
Error sound
J7
Not prepared
J8
Eco-operation (*9)
J9
Not prepared
JA
Not prepared
Jb
Not prepared
K1
Not prepared
K2
Not prepared
K3
Not prepared
K4
Not prepared
K5
Human sensor detection level (*11)
*1: The "02" setting may not be available according to the type of indoor unit.
*2: In case of RPI models, 00: standard, 01: high static pressure, 02: low static pressure
*3: E1 to E4: Setting for the total heat exchanger.
*4: In case that the set temperature is changed and kept within the set time at "F4", the temperature is automatically changed to "F5"
and "F6". (In case that the set temperature is out of range at "F5" and "F6", it is applied within upper and lower limit for the set
temperature.)
*5: Applicable to fan, cooling and dry operation modes.
*6: Applicable to heating operation mode.
*7: Operation is stopped by pressing the " " (run/stop) switch for 3 seconds.
*8: The value of the sensor selected by C8 setting will be displayed on the remote control. When the remote sensor is connected on
THM4, the average value of this remote sensor and of indoor unit inlet sensor will be displayed.
*9: When the unit is restarted by the remote control switch, the temperature automatically changes to the setting temperature of "F5"
or "F6".
*10: If function F2 is set up 01 (Sub) is displayed "--".
*11: This function is for air panel with motion sensor. If the air panel don't have available the motion sensor, setting condition is
displayed as "--".
?
N O T E
After at least 3 minutes from the power ON, change the optional setting.
When changing "CF" setting (change of louver swing range), restore the power supply or allow the louver to make one complete swing fully in the
auto swing mode to apply the optional setting.
The optional settings are different according to the indoor and outdoor unit models. Check to ensure that the unit has the optional setting or not.
Record the setting conditions for each optional setting in the "Setting" column of the table.
11
PMML0404A rev.1.1 - 06/2022
Individual setting Setting condition
-
-
-
-
-
-
00
×
01
-
-
-
-
00
×
01
-
-
00
×
01
-
-
×
-
00
×
01
-
-
00
×
01
-
-
-
-
-
-
×
-
×
-
×
-
-
-
00
-
01
02
Contents
Not used (Use as 00 conditions)
Not used (Use as 00 conditions)
Not used (Use as 00 conditions)
Indication
No indication
Not used (Use as 00 conditions)
Not used (Use as 00 conditions)
Not available
Available
Not Used
Green
Red
Not used (Use as 00 conditions)
Not used (Use as 00 conditions)
Once
Sequence
Not Used (Use as 00 conditions)
Not available
(*10)
Available
Not used (Use as 00 conditions)
Not used (Use as 00 conditions)
Not used (Use as 00 conditions)
Not used
Not used
Not used
Not used
Standard
High
Low