Attach the machines using nuts and bolts both at the rear (tabs) and at the front (holes in the side
panels accessed once the control holder panels have been removed) (see image).
Tie the machines with a bolt and a nut in the lower front part (see image).
Remove any excess sealant.
Remove the adhesive tape.
Replace the control holder panels and the controls.

4.4 Electrical connection

An AUTHORISED TECHNICIAN should always carry out the appliance's electrical connection.
The legal standards in force in each country regarding connection to the mains should be taken into
account.
• Check that the mains voltage corresponds to that indicated on the nameplate.
• The electric cable should be flexible, with an oil-proof covering, and it should not
weigh less than the cable in an ordinary sleeve made of standard polychloroprene
or an equivalent synthetic elastomer (H05RN-F).
• The cross-section of the power cable must be suitable for the rated current of the
machine. (Table 2)
• The appliance must be connected to earth using the connection on the appliance
connection terminal board. The earth cable should be longer than the other wires.
The manufacturer will not be held liable for damage originated by failure to observe
this requirement.
• When several appliances are installed in series, they should be earthed to each other
using the point assigned for this purpose, located at the rear of the appliance.
• An easily accessible omnipolar magneto-thermal circuit breaker of suitable capacity
should be installed next to the appliance, with a minimum gap of 3 mm between
contacts. This switch should be used to disconnect the appliance during installation,
repair, cleaning and maintenance work. It should have locking/labelling capacities.
The manufacturer will not be held liable for damage originated by failure to observe
this requirement.
• An easily accessible differential protection device of suitable capacity should be
installed next to the appliance. The manufacturer will not be held liable for damage
originated by failure to observe this requirement.