Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Résolution; Remote Sensor - Conrad Electronic BAR 923 Bedienungsanleitung

3-kanalfunk-wetterstation bar 923
Inhaltsverzeichnis

Werbung

Table of contents
1. Prescribed use ........................................................................................ 37
2. Scope of delivery .................................................................................... 37
3. Symbol explanation ................................................................................ 38
4. Safety instructions.................................................................................. 39
5. Battery and environmental notes .......................................................... 40
6. System description................................................................................. 41
7. Indicators and controls .......................................................................... 42
a) The front of the base unit .................................................................... 42
b) The rear of the base unit ..................................................................... 44
c) Remote sensor .................................................................................... 46
8. Commissioning ....................................................................................... 48
a) Inserting batteries into the remote sensor ........................................... 49
b) Inserting batteries into the base unit ................................................... 50
c) How to use the table stand and wall-mounting.................................... 51
9. Operation ................................................................................................. 52
a) General information............................................................................. 52
b) Switching between time/date display modes....................................... 52
c) Reading the temperature & indoor humidity........................................ 53
d) Display/Clear maximum/minimum values ........................................... 54
e) Auto scan function for remote sensors................................................ 54
f) Outdoor temperature trend indicator ................................................... 55
g) Toggling between °C/°F temperature units ......................................... 55
h) Barometric pressure trend indicator .................................................... 55
i) Weather trend indicator ....................................................................... 56
j) DCF time signal reception ................................................................... 57
k) Manual time/date setting ..................................................................... 58
l) Alarm time setting................................................................................ 60
m) Switching alarm on/off ......................................................................... 60
n) Alarm reaction, stopping the alarm...................................................... 61
10. Ranges and radio interference ............................................................ 62
11. Handling................................................................................................. 63
12. Maintenance and cleaning ................................................................... 63
13. Disposal ................................................................................................. 64
a) General information............................................................................. 64
b) Battery/rechargeable battery disposal................................................. 64
14. Technical specifications ...................................................................... 65
a) Base unit ............................................................................................. 65
b) Remote sensor .................................................................................... 65
15. Declaration of conformity (DOC) ......................................................... 66
36

14. Technical data

a) Base unit
Temperature measuring range:
Measuring range:.......................-5.0 °C to +50.0 °C (23.0 °F to 122.0 °F)
Resolution:.................................0.1 °C (0.2 °F)
Indoor humidity:
Measuring range:.......................25 to 95 % relative humidity
Resolution:.................................1 %
Number of remote sensors: ...........maximum 3
Temperature sensing cycle: ..........approx. 30 seconds
DCF reception:...............................DCF77 from Frankfurt on the Main
Clock mode: ...................................12 or 24 hours
Clock display:.................................hours/minutes/seconds, hh:mm:ss
Date display: ..................................day/month
Adjustable languages:....................weekday display in 5 languages
Power supply: ................................4 x Mignon (AA), alkaline batteries are
Weight:...........................................approx. 184 g
Dimensions: ...................................165 mm x 85 mm x 56 mm (H x W x D)
b) Remote sensor
Measuring range: ...........................-20.0 °C to +60.0 °C (-4.0 °F to 140.0 °F)
Resolution: .....................................0.1° C (0.2 °F)
Radio transmission frequency:.......433 MHz
Radio transmission range: .............maximum 30 meters
Temperature sensing cycle:...........approx. 30 seconds
Power supply: ................................2 x Micro (AAA), alkaline batteries are
Weight:...........................................approx. 54 g (without batteries)
Dimensions: ...................................92 mm x 60 mm x 20 mm (H x W x D)
Please note:
The manufacturer reserves the right to perform technical
modifications without prior notice.
at 25 °C (77 °F)
(English, German, Spanish,
French, Italian)
recommended
recommended
65

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis