Safe I/O Module, EtherNet/IP™ CIP Safety™
IP67 Module
When test output is activated, Muting Lamp feature controls the output current. Below 5mA, a fault is
detected and the status is 0=OFF. Above 25mA is normal operation, the status is 1=ON.
Below is a typical scenario for muting lamp broken wire detection:
Test Output Process Value
Step #1:
Step #2:
Step #3:
Step #4:
Typical wiring of safety inputs
M12 pining and wiring of the safety inputs with the associated pulse test outputs
1: Test Output #1 (TP1, 24 VDC powered from UB)
2: Safe Input #1 (IN1)
3: Ground Logic/Input (UB GND)
4: Safe Input #0 (IN0)
5: Test Output #0 (TP0, 24 VDC powered from UB)
www.balluff.com
Muting Lamp Physical State
1 = ON
1 = ON
0 = OFF
0 = OFF
Notes!
Only Test Output 3 and Test Output 7 can be configured in Muting Lamp
mode.
When Test Output is not activated, no broken wire fault can be detected.
However, once a default has been detected (step 2), the lamp
replacement is diagnosed even if the Test Output is deactivated (step 3)
Broken wire detection is performed at a 3 second period. Two
consecutive detections are required before the status is reported as BAD,
so up to 6 seconds can be required before muting lamp status to be set to
BAD
Lamp good
Lamp broken
Lamp broken
Lamp replaced
Muting Lamp Status
1
0
0
1
External Contact
1
2
TP1
IN1
TP0
1
5
GND
IN0
3
4
External Contact
25