Mode
Here, you can set the protocol to be used between the devices.
MA NET 1
If you only have MA LIGHTING devices (consoles of the grandMA series and the
„onPC" software) in the network, you can select MA Net as protocol.
at DMX OUT set the Merge Mode
NONE no merge
LTP = Latest Take Precedence
HTP = Highest Take Precedence
LoTP = Lowest Take Precedence
MA NET2 (It does not make sense here)
ARTNET
In order to cooperate with other lighting consoles, the 2Port Node can be run as
ARTNET Node. If you chose ARTNET, the Session ID cell will be greyed out (no
longer active). The ports will be OFF or Disabled, as long as no subnet and channel
is set.
In the TOOLS menu, press the DMX CONFIGURATION buttan and select the
DMX-OUTPUT via Ethernet menu.
Select the ARTNET protocol for the required Universe, and confirm with SAVE.
Back in the 2Port Configuration menu, set the ports.
Click on the port of the desired 2Port, which will open the Port Confiuguration
menu.
Select OFF, DMX IN or DMX OUT.
Click on the UNIVERSE cell and enter the subnet and port:
Syntax: SubnetPort e.g. 07 for subnet 0 and port 7 (see graphics)
For DMX OUT set the Merge mode
Don't get confused: ARTNET assigns individual IP numbers for the Nodes that are
not identical with the set IPs. This ARTNET IP will be assigned automatically and
cannot be changed. The ARTNET IP is of no importance when configuring the
2Port Node from a grandma console or the grandma onPC.