Legend
Charging curve without temperature
sensor connected
Charging curve with temperature sensor
connected
Mounting the battery
control booster
Installation location
A
NOTICE! Damage hazard
Before drilling any holes, ensure that no
electrical cables or other parts of the
vehicle can be damaged by drilling, saw-
ing and filing.
I
NOTE
The battery control booster can be
installed in any mounting position.
Observe the following instructions when selecting
an installation location:
• Ensure that the mounting surface is solid and
level.
• Observe the distance specifications (fig. 4,
page 4).
Using the display panel
The display panel can be mounted depending on
the installation position of the battery control
booster.
➤To rotate and reinsert the display panel in place
proceed as shown in fig. a, page 6.
➤To use the display panel as a remote control pro-
ceed as shown in fig. b, page 6.
18
Connecting the battery
control booster
The electrical power supply must be
connected by a qualified electrician who
has demonstrated skill and knowledge
related to the construction and opera-
tion of electrical equipment and installa-
tions and has received safety training to
identify and avoid the hazards involved.
!
WARNING! Electrocution hazard
Observe the recommended cable cross-
sections, cable lengths and fuse (see
table on page 19).
!
CAUTION! Fire hazard
Place the fuses near the batteries to pro-
tect the cable from short circuits and pos-
sible burning.
A
NOTICE! Damage hazard
Do not reverse the polarity.
I
NOTE
• In the case of two or more batteries,
• For Dometic Büttner LiFePO4 batter-
Observe the following instructions when connect-
ing the battery control booster:
• Select the appropriate connection variant.
Legend for fig. c, page 7 to fig. f, page 10:
4445103620
parallel connection is permissible if the
batteries are of the same type, capacity
and age. Connect the batteries diago-
nally.
ies: To ensure measuring the internal
temperature of the battery use the tem-
perature sensor connector to connect
the probe of the temperature sensor to
the negative terminal of the house bat-
tery.
House battery
Starting battery

Werbung