8

Troubleshooting

Risk of death due to electric shock!
Non-insulated parts may be touched when
the housing is removed in order to conduct
service work inside the machine. This work
may only be carried out by service personnel.
► Switch off the machine.
► Disconnect the mains plug.
If a malfunction cannot be eliminated with the
measures described in this chapter, contact Wei-
dmüller Service.

8.1 Fault table

Fault
Possible cause
Machine cannot be
The power supply is interrupted.
switched on
Machine switches off
The machine is overloaded.
during operation
Blade cuts into wire-end ferrule
Increased waste
The waste tray is full.
A stripping blade is damaged or
installed incorrectly.
An error message is shown on the display in case of faults.
► Correct the fault, see chapter 8.2.
Once the fault has been corrected, the machine is shown
as ready for operation.
48
WARNING
Recommended action
► Check the mains cable and the mains connection.
► Check the fuses.
► Switch off the machine.
► Remove the wire-end ferrule strip.
► Switch the machine back on and open the Service/
Jog mode menu.
► Move forwards or backwards.
► Check for further damage.
► Empty the waste tray, see see chapter 7.3.
► Check the fit of the stripping blade.
► Correct the position of the blade or exchange it,
see see chapter 8.4.