INSTALLATIoN
Installation
10. Installation
10.1 Removing the front panel
Remove the front panel before removing the appliance from the
pallet, to avoid damaging the casing.
2
1
1 Fascia
2 Front panel fixing screws
The fascia is fastened to the appliance with locking tabs.
f To disengage the locking tabs, press the grip areas on the
fascia sides.
f Remove the fascia from the appliance.
f Undo both screws securing the front panel at the top of the
appliance.
f Carefully push the front panel upwards by a small amount to
release it from the hooks on which it is engaged.
1 Plug on cable from programming unit to appliance
f Carefully raise the front panel by a small amount on the
right-hand side.
www.stiebel-eltron.com
f On the appliance, pull out the plug connecting the program-
ming unit with the appliance.
10.2 Mounting the appliance
Material losses
!
If the unit is not mounted horizontally, condensate cannot
2
drain properly. Condensate escaping in an uncontrolled
manner can damage the floor or items in the vicinity of
the unit.
Material losses
!
f Check whether the wall can bear the weight of the
f Use appropriate rawl plugs and screws suitable for
f Remove the wall mounting bracket from the appliance.
f Secure the wall mounting bracket to the wall with four
screws. The text "TOP" must be at the top. The wall mounting
bracket must be horizontal.
f If necessary, screw the star grips included in the standard
delivery into the back of the appliance at the bottom to act as
spacers.
f Fit the appliance onto the hooks of the wall mounting
bracket.
f If the appliance is not hanging horizontally, screw the previ-
ously fitted star grips acting as spacers in or out by a small
amount.
1
LWZ 180 | LWZ 280 | LWZ 180 Enthalpie | LWZ 280 Enthalpie |
appliance.
the wall structure to attach the rail.
47