oPERATIoN
Settings
4.3

Parameters adjustable from the home screen

4.3.1 Activating humidity protection
f In the home screen, turn the Touch-Wheel until "Humidity
prot." appears. Press "OK".
Humidity protection control is active. The moisture in the extract
air is measured and if humidity is high, the unit starts to ventilate.
4.3.2 Selecting the fan setting
f Using the Touch-Wheel, select the fan setting "Stage 1" or
"Stage 2". Press "OK".
The selected fan setting is active.
4.3.3 Activating time program mode
The "Time program mode" symbol indicates that the fan program
is activated.
f If the fan program is not activated, select "Time program
mode". Press "OK".
The displays shows the "Time program mode" symbol.
For times where there is no fan program defined, the unit operates
at fan stage 2.
Note
If you switch the unit to Time program modea fan pro-
gram must be entered in the "Programs" menu. Other-
wise the appliance continues to run without a time limit
in fan stage 2.
4.3.4 Switching on Intens. vent.
f Switch on Intens. vent. with the Touch-Wheel and the "OK"
button or with an external pushbutton.
When intensive ventilation is switched on, the "Intens. vent." sym-
bol is shown.
After expiry of the period of time set under "Intens. vent. time", the
unit switches back to the previously selected fan setting.
When intensive ventilation switches off, the "Intens. vent." symbol
goes out.
38
| LWZ 180 | LWZ 280 | LWZ 180 Enthalpie | LWZ 280 Enthalpie
4.3.5 Setting favourites
f Select "Favourites" using the Touch-Wheel. Press "OK".
This will take you from the standard view directly to the favourites
in the "Settings" menu.
f Select the required favourites. Press "OK".
The set favourites F1, F2 and F3 are displayed on the home screen.
4.3.6 Activating function block
f Select "Function block" using the Touch-Wheel. Press "OK".
A 60 second countdown and "Maintenance" are displayed.
Then you can wipe the programming unit clean without inadvert-
ently changing any settings. The function blockterminates after
60 seconds.
4.3.7 Direct selec.
Use direct selection to move from the standard view directly to
the adjustable or readable parameters.
f Select "Direct selec." using the Touch-Wheel. Press "OK".
Note
The table shows only the direct selection parameters to
be set by the appliance user. The other direct selection
parameters shown on the display may only be set by a
qualified contractor or the service department.