STIEBEL ELTRON LWZ 180 Bedienung Und Installation Seite 52

Zentrales lüftungsgerät mit wärmerückgewinnung
Vorschau ausblenden Andere Handbücher für LWZ 180:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATIoN
Settings
12.1.1 "Info" menu
Info
Bypass status
Extract air temp.
Extract air hum.
Extract air dew pt
Outdoor air temp.
Outdoor air hum.
Outdoor air dew pt
Supply air temp.
Exhaust air temp.
Supply air fan control
Supply air fan speed
Supply air flow rate
Exhaust air fan control
Exhaust air fan speed
Exhaust air flow rate
Heating coil control
Extract air diff. press.
12.1.2 "Diagnostics" menu
Diagnostics
Notification list
Clear notification list
Filter runtime
Filter reset
Filter change interval
Device operating time
Fan operating time
Diagnostics
Clear notification list
To clear the notification list, set this parameter to "On". Press "OK"
to confirm. Afterwards, "Off" is displayed again and the fault mes-
sages are deleted.
12.1.3 "Programs" menu
Programs
Fan program
12.1.4 "Settings" menu
Settings
View
General

Time/date
52
| LWZ 180 | LWZ 280 | LWZ 180 Enthalpie | LWZ 280 Enthalpie
Value
Off | On
°C
%
°C
°C
%
°C
°C
°C
%
rpm
m³/h
%
rpm
m³/h
%
Pa
Value
Off | On
h
Off | On
d
d
d
Value
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday - Friday
Saturday - Sunday
Monday - Sunday
Value
Code for qualified con-
tractor
Day
Hour:Minute

Language

Contrast

Brightness

Touch sensitivity

Touch boost

Prog. unit software
Fan control

Constant flow rate

Constant pressure
Air flow rate

Flow rate, stage 0

Flow rate, stage 1

Flow rate, stage 2

Flow rate, stage 3

Supply air flow rate offset
Extract air diff. press.

Diff. pressure, stage 0

Diff. pressure, stage 1

Diff. pressure, stage 2

Diff. pressure, stage 3
Favourites

F1
F2
F3
Humidity prot.

Enable humidity control (A2)

Humidity prot. interval

Humidity threshold

Humidity capture delay
Intensive ventilation

Intens. vent. time
Heat recovery bypass

Set room temperature

Operating mode heat recovery bypass

Temperature to enable heat recovery by-
pass

Temperature to block heat recovery bypass °C

Hysteresis for heat recovery bypass

Temp. differential for heat recovery bypass K

Window contact mode (A2)
(depending on unit)

Cooling/heating, heat recovery bypass
Frost protection

Frost protection temp.

Temp. to enable frost protection (A2)
German
English
Francais
Nederlands
Italiano
Polski
Cesky
Magyar
Slovensko
中文
Slovensky
日本語
1 - 10
%
1 - 10
m³/h
m³/h
m³/h
m³/h
m³/h
Pa
Pa
Pa
Pa
F1, F2, F3
Bypass status
Extract air temp.
Extract air hum.
Filter runtime
Device software version
Device software patch
Term. device serial no.
Only for qualified con-
tractors
Off
On
h
%
min
min
°C
Disabled
Bypass/window contact
Outdoor air routing au-
tomatic
Extract air routing autom.
°C
K
Without window contact
With window contact
Cooling/heating
Cooling
Heating
Only for qualified con-
tractors
°C
°C
www.stiebel-eltron.com