Caution!
The maximum permitted duty cycle in low impedance operating
mode is 5 seconds for voltage up to 250 V and 3 seconds for
voltages up to 690V. When this time has lapsed, wait for
10 minutes.

5. Replacing the batteries

*
Short the Test-probes to test and if no signal is heard or the
AUTO-test no longer works, the batteries should be replaced
*
Disconnect the voltage detector completely from any power
source
*
Open the battery compartment with the cross-bolt on the
bottom of the unit
*
Remove the battery cover off down
*
Replace the batteries with new ones of the same type ("AAA"
(UM4 R03) 1,5 V)
*
Ensure the correct battery polarity
*
Close the battery compartment and re-screw the cover
completely