5.6.
OPERATION
5.6.1.
Starting
r
OTATINg
Danger of body parts being pulled in
•
Keep the device covers closed.
•
When working on the device, switch the engine off.
Switch the engine off
Provide first aid in accordance with guidelines and/or notify first responders
Before starting the power generator, perform the tests that must be done before putting into
•
- Engine oil level
•
- Fuel level
•
- Correct connection of the consumers
•
Switch the fuel tap (21-8 respectively 21-18) to either the integral tank or, when fitted, the exter-
nal fuel supply system.
•
Switch the automatic circuit-breakers on.
•
Turn the main switch (22-12) to the "I" position
5.6.2.
Electrical start-up
If the engine does not fire within 5 seconds, release the main switch and wait at least 10 seconds
If the electric starter is run for longer than 5 seconds this will lead to the starter overheating and
•
There is no need to set the choke since this is operated automatically.
•
Turn the main switch to the "Start" position and hold it there until the engine fires.
•
Switch the connected consumers on.
I
CAUTION
M
p
ACHINE
ArTS
NOTE
operation. In particular, check:
NOTE
before attempting again to start the engine.
possible damage
Page 31