Herunterladen Inhalt Inhalt Diese Seite drucken

Control/Refreshing Of Oil Level And Pump Oil; Control/Refreshing The Reduction Oil - Oil Level; Maintenance Petrol Motor; Cleaning Of The Water Filters - Dibo PTL-S serie Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Control/refreshing of oil level and pump oil

3
Check for each use of the machine the oil with the oil level glass or with the oil
level bar. oil must stand right with the sign of the oil level glass, if the this case
is not, oil tops up until the sign. If oil looks forward to there milky, consult directly
the DiBo technicians. To refresh oil, as follows work goes:
• unbolt the drain plug below the pump.
• unbolt the tap with the oil level bar.
• Catch all oil in a barge and remove oil like further described in the guide.
• Force up the drain plug there and top up the oil in the breach to the upper
part to on the mark line.
• Force up the tap with the oil level bar there.
• Recommended oil: 1.836.042.

Control/refreshing the reduction oil - oil level

4
Check for each use the machine the oil with the oil level glass. oil must stand
right with the sign of the oil level glass, if the this case is not, oil tops up until the
sign. If oil looks forward to there milky, consult directly the DiBo technicians. To
refresh oil, as follows work goes:
• unbolt the drain plug below the reduction gearbox.
• Catch all oil in a barge and remove oil like further described in the guide.
• Force up the drain plug there and top up the oil in the breach to the upper
part to on the mark line.
• Recommended oil: 1.836.015.

Maintenance petrol motor

5
For maintenance activities to the petrol motor we guess to consult the supplied
instructions for use of the motor. Recommended oil: 1.836.010.

Cleaning of the water filters

6
Clean the water filters regular and remove possible dirt.

Maintenance at expense/DiBO technicians

7
For further maintenance we advise to contact your DiBo distributor concerning
a maintenance contract. The maintenance applies to normal company
circumstances. at heavy circumstances you can communicate this so that can
be taken into account. Supplement documents:
• Control manual
• CE- certificate
• Electrical plans
Remarks: It is recommend the preventive maintenance to carry out by a
competent DiBo- service technician according to this maintenance diagram,
to be able to remain use the machine up to maximum and also to be able to
claim the guarantee conditions. To be able to guarantee a good and regular
maintenance, we advise the owner/user at strongest to make an appointment
with DiBo against reaching the given up company hours, concerning a
maintenance turn.

DESCRIPTION DAILY CONTROL

Frame

1
Check the frame in its entirety at loose bolts and/or cracks of the welds.
keep the machine as much as possible clean to prevent act on dirt, water, oil
and messed fuel.

Valves + manometer

2
at an switched off machine, this means a halted engine, the manometer must
reflect 0 bar. at an maximum performing machine, this means operated at full
load working engine, the manometer can not indicate more than the maximum
pressure by DiBo indicated, for your machine. after operation and releasing
the gun can still remain a small pressure remainder present. The reflected value
of the manometer must be between 0-30 bar, the valves are then all right.
DiBO 21
E N
S E R V I C E    

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ptl-s 100/11 bPtl-s 150/11 b

Inhaltsverzeichnis