    S E R V I C E

Periodic maintenance

2
DESCRIPTION
Control of the electric cables, high and low pressure
hoses and coupling and control of the oil level.
Refreshing pump oil.
Cleaning water filter.
all following refreshments of pump oil and service
on the cleaner.
Extra control/replacement of joints, valves, o- rings
by acknowledged DiBo- technicians.

Control of oil level / refreshing of pump oil

3
Check for each use of the machine the oil by way off oil level glass or with the
oil level bar.
oil must stand right with the sign of the oil level bar, if the this case is not, oil
tops up until the sign.
If oil looks forward to there milky, consult directly the DiBo technicians. To
refresh oil, as follows work goes:
• unbolt the drain plug below the pump.
• unbolt the tap with the oil level bar.
• Catch all oil in a barge and remove oil.
• Force up the drain plug there and top up the oil in the breach to the upper
part to the right level.
• Force up the tap with the oil level bar there. Recommended oil: 1.836.042.

Cleaning of the water filters

4
Clean the water filters regular and remove possible dirt.

Maintenance at expense of DiBO technicians

5
For further maintenance (burner, engines, high pressure pump and parts who
has to do with safety) we advise to contact your DiBo distributor concerning a
maintenance contract.
The maintenance applies to normal company circumstances.
at heavy circumstances you can communicate this so that can be taken into
account.
Supplement documents:
• Control manual
• CE- certificat
Remarks:
We advise the owner/user at strongest to make an appointment with DiBo
against reaching the given up company hours, to be able to guarantee a good
and regular maintenance concerning a maintenance turn.

DESCRIPTION DAILY CONTROL

Frame

1
Check the frame in its entirety at loose bolts and/or cracks of the welds.
keep the machine as much as possible clean to prevent act on dirt, water, oil
and messed fuel.

Valves + manometer

2
at an switched off machine, this means a halted engine, the manometer must
reflect 0 bar.
at an maximum performing machine, this means operated at full load working
engine, the manometer can not indicate more than the maximum pressure by
DiBo indicated, for your machine.
after operation and releasing the gun can still remain a small pressure
remainder present.
The reflected value of the manometer must be between 0-30 bar, the valves are
then all right.
DiBO 20
PERIOD
after each use.
First 50 hours. .
Each 50 hours/every
month.
Each 400 hours/
yearly.
Each 600 hours.

Werbung