Herunterladen Inhalt Inhalt Diese Seite drucken

Switching Off The Fan Heater; Overheating Protection; Troubleshooting; Maintenance, Cleaning And Storage - Parkside PKH 3000 A1 Bedienungs- Und Sicherheitshinweise

Vorschau ausblenden Andere Handbücher für PKH 3000 A1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 56
highest temperature range
Please note: The fan heater temporarily remains very
hot during the heating intervals. Please take care when
operating the fan heater.
The fan heater has angle adjustment. Turn the rotary
knobs 6 at the side to adjust the tilt.

Switching off the Fan Heater

To avoid heat build-up in the fan heater, allow
the fan to run for approximately 30 seconds
afterwards.
Turn the heating level switch 2 to position 0.
Pull out the mains plug to disconnect the heater from
the mains supply, thus switching it off completely.

Overheating Protection

This fan heater is equipped with overheating pro-
tection. If the fan heater overheats, it will switch off
automatically. The fan continues to run so that rapid
cooling is achieved. The fan heater will switch on
again automatically once it has cooled down properly.
PLEASE NOTE: There is usually a reason for
overheating! It can indicate a fire hazard!
Check whether the fan heater is giving off suffi-
cient heat: Is the fan heater covered or is it too
close to a wall or other obstruction? Is the grid
blocked in the front or at the back? Is the fan
blocked?
Rectify the problem if possible, or contact the
service hotline (see the section "Service").
Even if you were unable to identify the cause, if
the overheating protection is triggered a second
time, you must switch off the fan heater and con-
tact the service hotline (see "Service" Section).

Troubleshooting

Fault
Possible cause
The fan
The mains plug
heater
is not plugged in.
will not
Socket delivering
switch on.
no voltage.
The fan
Heating level
heater
switch 2 is not
does not
switched on.
heat up.
Temperature con-
trol 4 is in the
MIN position.
Faulty heating
element.
M aintenance, Cleaning
and Storage
Always disconnect the mains plug when the fan
heater is not in use, before cleaning or in the event
of operating faults!
Clean the fan heater only when switched off and
cold.
Make sure when cleaning that no moisture pen-
etrates into the fan heater, to avoid irreparable
damage to the fan heater.
Clean the housing with a slightly damp cloth and a
mild detergent.
Use a vacuum cleaner to remove dust from the
safety guard.
Store the heater in a dry environment.
Solution
Insert the mains
plug in the socket.
Check the
house fuses.
Set the heating
level switch 2
to the desired
operating mode.
Set temperature
control 4 to the
MAX position.
Notify customer
services.
GB 11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis