PSEN cs1.13p ATEX
Environmental data
Airgap creepage
Overvoltage category
Pollution degree
Rated insulation voltage
Rated impulse withstand voltage
Protection type
Housing
Mechanical data
Actuator 1
Operating distances
Assured operating distance Sao
Typical operating distance So
Assured release distance Sar
Typical release distance Sr
Repetition accuracy switching distances
Change of operating distance with temperature
changes
Typ. Hysteresis
Min. distance between safety switches
Sensor flush installation in accordance with EN
60947-5-2
Connection type
Material
Top
Max. torque setting for fixing screws
Dimensions
Height
Width
Depth
Actuator dimensions
Height
Width
Depth
Weight of safety switch
Weight of actuator
Weight
Where standards are undated, the 2014-10 latest editions shall apply.
Safety characteristic data
Operating Manual PSEN cs1.13p ATEX
21097-2EN-13
III
3
75 V
1 kV
IP67
PSEN cs1.1
15 mm
21 mm
40 mm
32 mm
10 %
+-0,01mm/°C
3 mm
400 mm
Yes, follow installation guidelines
M12, 8-pin male connector
PBT
1 Nm
75 mm
40 mm
40 mm
11 mm
40 mm
40 mm
130 g
20 g
150 g
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
45