The supply voltage to the safety switch must be protected with a 2 A to 4 A quick-acting
fuse.
}
Ensure the EMC requirements of IEC 60204-1 are met.
}
When connecting in series, make sure you comply with the wiring technology require-
ments (DIN EN 60204-1) and manipulation protection requirements (EN ISO 14119).

Pin assignment, connector and cable

PIN
1
2
3
4
5
6
7
8
The wire colour also applies for the cable available from Pilz as an accessory.

Connection to evaluation devices

Make sure that the selected evaluation device has the following properties:
}
Dual-channel with feasibility monitoring
}
OSSD signals are evaluated
Operating Manual PSEN cs1.13p ATEX
21097-2EN-13
INFORMATION
Only use safety relays with a 24 VDC supply voltage. Safety relays with uni-
versal power supply or in AC device versions have internal potential isola-
tion and are not suitable as evaluation devices.
CAUTION!
Do not connect the signal output to 0 V!
If the signal output Y32 is connected to 0 V, the safety switch may be dam-
aged as a result. Connect the signal output Y32 to a consumer, e.g. to the
input on a control system, or leave the signal output unconnected.
Pin
designation
Function
S21
Input, channel 2
A1
+24 VUB
12
Output, channel1
22
Output, channel2
Y32
Signal output
S11
Input, channel 1
A2
0 V UB
-
Do not connect
8-pin M12 connector
Wire colour
white
brown
Green
yellow
grey
Pink
blue
red
35