Mechanical data
Actuator dimensions
Height
Width
Depth
Weight of safety switch
Weight of actuator
Weight
Where standards are undated, the 2014-10 latest editions shall apply.

Safety characteristic data

Operating
EN ISO
mode
13849-1:
2008
PL
2-ch. OSSD PL e
All the units used within a safety function must be considered when calculating the safety
characteristic data.
Operating Manual PSEN cs2.13p ATEX
21133-2EN-1
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
EN ISO
EN 62061
13849-1:
SIL CL
2008
Category
Cat. 4
SIL CL 3
INFORMATION
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
11 mm
40 mm
40 mm
130 g
20 g
150 g
EN 62061
IEC 61511
PFH
[1/h]
SIL
D
4,10E-09
SIL 3
IEC 61511
EN ISO
13849-1:
PFD
2008
T
[year]
M
1,10E-04
20