PSEN cs1.13p ATEX
For your safety
}
Do not remove the connector's protective cap until you are just about to connect the
unit. This will prevent potential contamination.
Unit features
}
Transponder technology for presence detection (safety function)
}
Pilz coding type: Coded
}
Dual-channel operation
}
2 safety inputs for series connection of multiple safety switches
}
2 safety outputs
}
1 signal output
}
LED display for:
–
–
–
}
4 directions of actuation
Function description
The safety outputs may have a high or low signal, depending on the position of the actuator
and the signal status of the inputs.
In a safe condition there is a low signal at the safety outputs.
Electrical states of the inputs and outputs (when switch is ready for operation:
Power / Fault LED is green):
Actuator in
the re-
sponse
range
Yes
Yes
No
Operating Manual PSEN cs1.13p ATEX
21097-2EN-13
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
– You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
– Keep the spare actuator in a safe place and protect it from unauthor-
ised access.
– If spare actuators are used, these must be installed as described in
Installation [
State of the actuator
State of the inputs
Supply voltage/fault
Safety input
S11
High
Low
X
39].
Safety input
Safety out-
S21
put 12
High
High
Low
Low
X
Low
Safety out-
Signal out-
put 22
put Y32
High
High
Low
High
Low
Low
31