Safety

Intended use

The safety switch is approved for use in potentially explosive atmospheres in accordance
with EN 60079‑0, EN 60079‑15, EN 60079‑18, EN 60079‑31
Ex area Group II, Category 3G, Zone 2 (Gas): II 3G Ex mc nAc IIC T6 and Category 3D,
Zone 22 (dust): II 3D Ex mc tc IIIC T80°C IP67.
Safety function of safety switch:
}
2 safety outputs, each of which supply a high signal when the actuator is in the safety
switch's response range and when there is a high signal at the safety inputs.
The safety switch meets the requirements in accordance with:
}
EN 60947-5-3 with the actuator PSEN cs1.1 : PDDB
}
EN 62061: SIL CL 3
}
EN ISO 13849-1: PL eCat. 4
}
EN ISO 14119: Coding level Low, Type4
The safety switch may only be used with the corresponding actuator PSEN cs1.1.
The safety level PL e (Cat. 4 )/SIL CL 3 is only achieved if
}
the safety outputs use 2-channel processing.
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the product
}
Use of the product outside the areas described in this manual
}
Use of the product outside the technical details (see
Operating Manual PSEN cs1.13p ATEX
21097-2EN-13
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Technical details [
43]).