Verfügbare Sprachen

Verfügbare Sprachen

PSEN cs1.13p ATEX
}
PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.
}
PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_Safety Gate
}
PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate
The correct connection to the respective evaluation device is described in the instructions
for the evaluation device. Make sure that the connection is made in accordance with the
specifications in the instructions for the selected evaluation device.
The connections to two evaluation devices are shown on the following pages, by way of ex-
ample:
}
PNOZ s3 and
}
PNOZmulti
PNOZ s3
PNOZmulti
Operating Manual PSEN cs1.13p ATEX
21097-2EN-13
PNOZ s3
A1
A2
S12
S22
PNOZmulti
A1
A2
I0
I1
I2
PSENcode
A1
2
7
A2
5
Y32
8
n.c.
6
S11
1
S21
3
12
4
22
PSENcode
2
A1
7
A2
n.c.
8
6
S11
1
S21
grün
3
12
gelb
4
22
grau
5
Y32
38