Herunterladen Inhalt Inhalt Diese Seite drucken

Teaching In The Actuator; Installation - Pilz PSEN cs1.13p ATEX Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für PSEN cs1.13p ATEX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PSEN cs1.13p ATEX
Legend:
I0
I1
I2

Teaching in the actuator

Any Pilz actuator PSEN cs1.1) is detected as soon as it is brought into the response range.

Installation

}
The safety switch and actuator should be installed opposite each other in parallel.
}
Safety switches and actuators should be permanently secured using M5 safety screws
with a flat head (e.g. M5 cheese-head or pan head screws).
}
Protect the actuator from contamination.
}
Torque setting: Please note the information provided under
}
The distance between two safety switches must be maintained (see
details [
}
Make sure that the safety switch and actuator cannot be used as an end stop.
Installation example:
The full face of the safety switch is installed on the subplate.
As a result, the edges of the safety switch base are protected from shock.
Operating Manual PSEN cs1.13p ATEX
21097-2EN-13
Input OSSD
Input OSSD
Signal input
CAUTION!
The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material. Please check the oper-
ating distances and the assured release distance.
43]).
Technical details [
43].
Technical
39

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis