Installation

4.3 Mounting the magnetic sensor

Alignment of the magnetic sensor
NOTICE
` Take care that the magnetic sensor is aligned correctly in order to
1. Mount the magnetic tape (see chapter 4.2).
2. Magnetic sensor can be fastened by using two bolts over the elongated
3. Place distance gauge with its complete surface between sensor and
3
Fig. 6: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances
LE200 · Date 15.01.2020 · Art. No. 84882 · Mod. status 7/20
ensure optimum sensing (see
holes (for the fastening dimensions refer to the Data Sheet). We rec-
ommend to use the enclosed fixing screws and washer springs (fasten-
ing torque = 1 Nm).
magnetic tape. Note: only relevant for sensors without reference sig-
nal RB, RD.
2
<1°
5
MBxxxx GEK WT RP NNNNNN
Fig.
6).
1
4
Active side magnetic tape
1
Travel direction sine before
2
<3°
cosine
(<1°*)
Direction of outgoing cable
3
Admissible deviation of tape/
4
sensor
0.1 ... 0.8 mm reference point
O, IA, ID
0.1 ... 0.5 mm reference point
RB, RD
Maximum alignment error
5
Position of the reference
6
point relating to the marking
on the magnetic tape
* with fixed reference signal "RB"