18

Identification

CAUTION
CAUTION
CAUTION
NOTICE
External magnetic fields
Failures and data loss occur if strong magnetic fields influence the internal
measuring system.
` Protect the magnetic sensor from impact by external magnets.
3 Identification
Please check the particular type of unit and type number from the identifi-
cation plate. Type number and the corresponding version are indicated in
the delivery documentation.
e. g.
-
LE200
0023
The magnetic tape is identifiable by a consecutive imprint.
e. g.
MBxxxx GEK WT RP NNNNNN

4 Installation

4.1 Mechanical mounting

Magnetic sensor failure
` When mounting pay attention to the IP type of protection (see chap-
ter 8).
` Do not open the sensor yourself.
` Avoid blows to the unit.
` Do not modify the device in any way.
` The cable must be provided with strain relief. If necessary use drag
chain or protective sleeve.
Loss of measured values
` The tolerances and distance dimensions must be observed over the
whole measurement length.
` The max. gap without cover strip is 0.8 mm (with reference point max.
0.5 mm). When using cover strip, the gap is reduced by the thickness
of cover strip including its adhesive tape. Sensor must not touch the
magnetic strip.
LE200 · Date 15.01.2020 · Art. No. 84882 · Mod. status 7/20
variant number
type of unit
batch number
reference point
material carrier tape
accuracy
MB type
English