MSK400/1
20
Installation
NOTICE
4.3 Mounting the magnetic sensor
Alignment of the magnetic sensor
` Take care that the magnetic sensor is aligned correctly in order to
ensure optimum sensing (see
1. Mount magnetic tape (see chapter 4.2).
2. Fasten the magnetic sensor, via the thru-holes (2x ø3.5 mm) on an
even work surface (for the fastening dimensions refer to the Data
Sheet). We recommend to use the enclosed fixing screws and washer
springs (fastening torque = 0.25 Nm).
LINEAR application:
MSK400/1 with MB400:
±3°
Fig. 6: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances
MSK400/1 · Date 07.02.2018 · Art. No. 81145 · Mod. status 44/18
Fig.
6).
Active side magnetic tape
1
Travel direction signal A
2
±3°
before B
Direction of outgoing cable
3
Admissible deviation of
4
tape/sensor 0.1 ... 4 mm
Maximum alignment error
5
English