No.
Designation of the
safety feature
6
Power and oxygen
shortage fuse
7
Excessive rise in room
temperature
8
Overheating fuse for
high burning temperatures
9
Oil supply alarm
10
Fan protection device
11
Problem with combustion –
operation stopped
12
Non-ignition fuse
28
Description
The fuse switches off because of lack of power, falling off o
the flame and insufficient oxygen. The display will show E0
and VENT. The fuse can be deactivated by pressing the OF
button.
The heater will stop operating if the room temperature rises
above 30° C. The display will show E14. The room
temperature fuse is at the back of the heater. The fuse can
deactivated by pressing the OFF button.
In the event of overheating the burner will be turned off by t
thermostat in the burner. The display will show 05. To
deactivate the fuse, pull out the mains plug and reinsert. To
cool the burner down, let the fan motor run for 2 minutes.
The alarm will be triggered when the remaining liquid fuel in
the supply tank is lower than the minimum level. The heate
will switch from high to low output and stop after 40 minute
The display will show E07 – FUEL. To cancel the alarm, pr
the OFF button, fill up the receiver tank and restart. If the ro
temperature has fallen below 30° C, operate the heater at f
burning output.
If the fan speed is slower than the set speed, insufficient
combustion will result. The heater then stops and the displa
will show E12. Press the OFF button to deactivate the
protection device.
The speed of the fan motor is abnormal or the temperature
combustion is lower than the set level. The display will show
E08. Press the OFF button to deactivate the fuse.
This stops combustion, because no flame was recognized
the length of the flame was too short.
The display will show E09.
Press the OFF button to deactivate the fuse.