No.
Function
5
Program temperature display
6
Ventilation display
7
FUEL display
8
Setting the time
9
Temperature control function
10
Off function

12. Description of safety features

No.
Designation of the
safety feature
1
Automatic cut-out fuse
2
Overheating protection
3
Over-voltage protection
4
Power failure fuse
5
Ignition fuse
Description
This shows the required temperature.
The range is 0 – 30° C.
* When the heater is used for the first time there is p
set temperature of 20° C.
This lights up when excessive carbon monoxide lev
have been reached, resulting from poor combustion
a lack of fresh air inflow. The display will show "E04
VENT.
If the kerosene has been used up, a warning signal
sound and the display will show "E07" FUEL.
The current time can be adjusted. AM and PM can
set separately. The display will show AM:PM, minut
and hours.
This is used to set the required temperature.
The display will show 12 – 30° C.
This is used to turn the heater off, or to stop smells
and non-burnt gas when you are not at home, with
hot air fan being turned off 10 seconds beforehand.
This ensures slow reduction of the flame during
operation and so prevents the flame being
extinguished quickly.
Description
The cut-out device switches the burner off when the
temperature level is between 7 – 20° C. The display will sho
E06. To deactivate the cut-out fuse, press the OFF button.
This is for turning the flame off if the heater becomes
overheated by the burner.
This turns off the heater in the event of over-voltage. The fu
has a capacity of 250 V – 5A / 630 mA. If necessary, chang
the fuse and restart (only to be carried out by an electrician)
This fuse is triggered by power failure, if the heater is in
operation. The display shows 000 when power is available
again. Press the 3 hour ON button or the ON button to resta
The ignition fuse may be triggered in the event of poor igniti
during the ignition operation. Flame monitoring controls this
operation.
The display shows E003. The fuse can be deactivated by th
OFF button.