Problems
There is a sound like running water.
Dripping fuel.
FUEL warning light lights up, even though
there is sufficient fuel in the tank.
What do the following symptoms mean?
When
The heater stops after a certain
period of operation when in
"Programmed Operational Time".
FUEL light flashes.
The heater stops after
a certain time.
The display does not light up.
24
Causes and solutions
This can be the result of the kerosene flowing from t
supply tank to the consumption tank. This is normal.
Check the sealing cap of the tank and tighten prope
Check whether there is water in the tank or if other
substances have collected on the oil filter. If so, rem
them.
Because
The safety system is activated
after 1 hour of operation.
Fuel is running out.
The safety system is activated
after more than 3
hours of operation.
The mains plug is not inserted.
Causes/Remedies
Press the ON or 3 HR ON butto
Press the STOP button, refill wit
kerosene and restart.
Press the 3 HR ON
button for a further 3 hours of
operation, or press ON for
continual operation.
Insert the mains plug in the plug
socket.